Communications
125
14 RS232 Port
Busy
The RS232 port is already in use; for example, the modem is
currently connected.
16 SMS not
successfully
sent to all
numbers
The SMS message was not successfully sent to all the phone
numbers for which it was configured.
17 PUK number
needed
The SIM card is locked due to too many attempts to enter an
incorrect PIN number.
SMS messaging problems
You can begin troubleshooting by entering Information Mode. You can then check the
status of relevant System Bits and Integers to help diagnose the problem.
To begin diagnosing the problem, check the error codes contained in SI 70 and SI 180.
Refer to the error code tables Modem Communications-- System Bits and Integers and in
SMS System Bits and Integers
The tables below show the more common causes of SMS communication problems.
Problem SI 70 value Possible Cause & Recommended Action
Modem fails to
initialize
2: Modem
Did Not
Reply
M90-to-GSM modem cable:
Make sure that the cable is securely connected. Check
the pin-out. of the M90-to-modem adapter cables. Note
that if you use cables comprising this pin-out, you
must set the RS232 parameter Flow Control to N
(none).
Incompatible communication settings.
Most modems automatically match the parameters of
incoming data: baud rate, data bits, parity & stop bits.
The M90's embedded GSM modem settings are: 19200,
8 data bits, no parity, 1 stop bit. You may need to
manually change your modem's communication
settings to match these.
0: No Error SB 72 / SB180: OFF
In order to work with a GSM modem , you must select
'Use GSM modem' in the SMS configuration box . This
causes SB 72 Initialize Modem and SB 180 Initialize
GSM modem to turn ON when the M90 powers up.
Check that these SBs are not disabled in your
program.
6: Modem
Report Error
Check the modem initialization commands. Refer to
Configuring the M90 to use a modem.
Other Common Problems:
Problem SI 180
value
Possible Cause & Recommended Action
GSM modem not
Initialized
1 Refer to table above
Wrong PIN
number
5 Check the PIN number contained in the SMS
Configuration box, leave it empty if your SIM card has no
PIN number.
Failed
Registration
6
GSM modem did not register successfully, for example if
no network was found, or if the modem antenna is not
functioning.
PUK number
needed
17
The SIM card is locked due to too many attempts to enter an incorrect
PIN number.
Cell phone does
not receive
No value Check the cell phone's SIM card; it may be full. You
can clear the SIM card using SB 193 Delete all SMS
Vista de pagina 132